Parameter |
Value |
AC voltage |
6 V, 60 V, 600 V, 750 V; Resolution 0.001 V, 0.01 V, 0.1 V, 1 V |
Accuracy of AC voltage measurement |
±(1,2 % + 5), range: 6 V, 60 V, 600 V ±(1,5 % + 5), range 750 V |
DC voltage |
600 mV, 6 V, 60 V, 600 V, 1000 V; Resolution 0.1 mV, 0.001 V, 0.01 V, 0.1 V, 1 V. |
Accuracy of DC voltage measurement |
±(1 % + 8), range: 600 mV; ±(0,8 % + 1), range: 6 V; ±(0,8 % + 3), range: 60 V, 600 V ±(1 % + 3), range: 1000 V |
AC current |
6 A, 60 A, 600 A; Resolution 0.001 A, 0.01 A, 0.1 A |
Accuracy of AC current measurement |
±(2,5 % + 30), range: 6 A ±(2,5 % + 5), range: 60 A, 600 A |
Resistance measurement |
600 Ω, 6 kΩ, 60 kΩ, 600 kΩ, 6 MΩ, 60 MΩ |
Accuracy of resistance measurement |
±(1,2 % + 2), range: 600 Ω ±(1,2 + 2), range 6 kΩ,60 kΩ, 600 kΩ ±(1,2 % + 2), range 6 MΩ ±(1,5 % + 2), range60MΩ |
Capacity measurement |
99.99 nF, 999.9 nF, 9.999 μF, 99.99 μF, 999.9 μF, 9.999 mF, 59.99 mF |
Accuracy of capacity measurement |
±(4 % + 25), range: 99.99 nF ±(4 % + 5), range: 999.9 nF, 9.999μF, 99.99μF, 999.9 uФ ±(10 %), range: 9.999 mF Mot defined for range 59.99 mF |
Diode test |
Yes |
Continuity test |
Yes |
NCV |
Yes |
Clamp diameter |
30mm |
Display |
LCD |
Working temperature |
0 – 40 °С |
Storage temperature |
- 20 – -60°С |
Working humidity |
80 %,0 – 30 °С 75,30 – 40 °С 45,40 – 50 °С |
Power source |
3xAAA 1.5V battery |
Size |
228 x77 x 41 mm |
Weight |
265 g (including battery) |