Parameter |
Value |
AC voltage |
6 V, 60 V, 600 V, 750 V; resolution 0.001 V, 0.01 V, 0.1 V, 1 V |
Accuracy of AC voltage measurement |
±(1.2% + 5), range: 6 V ±(1.2% + 3), range: 60 V, 600 V ±(1.5% + 5), range: 750 V |
DC voltage |
600 mV, 6 V, 60 V, 600 V, 1000 V, resolution 10 µV, 0.1 mV, 1 mV, 10 mV, 0.1 V, 1 V |
Accuracy of DC voltage measurement |
±(0.8 % + 3), range: 600 mV, 6 V, 60 V, 600 V ±(1 % + 5), range: 1000 V |
AC current |
200A, resolution:0.1A. |
Accuracy of AC current measurement |
±(2.5%+5) |
DC current |
200A, resolution0.1A |
Accuracy of AC current measurement |
±(2.5%+5) |
Resistance |
600 Ω, 6 kΩ, 60 kΩ, 600 kΩ, 6 MΩ, 60 MΩ, resolution 0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ. |
Accuracy of resistance measurement |
±(1.2 % + 2), range: 600 Ω ±(1 % + 2), range: 6 kΩ, 60 kΩ, 600 kΩ ±(1.2 % + 2), range: 6 MΩ ±(1.5 % + 5), range 60 MΩ |
Electric capacity |
60 nF, 600 nF, 6 nF, 60 μF, 600 μF, 6 mF, 60 mF, resolution: 0.01 nF, 0.1 nF, 0.001 nF, 0.01 μF, 0.1 μF, 0.001 mF, 0.01 mF |
Accuracy of capacity measurement |
±(4%+20), range: 60 nF, 600 nF, 6μF, 60μF, 600 μF ±10 %, range: 6 mF Not defined for range 60 mF |
Diode test |
Yes |
Continuity test |
Yes |
NCV |
Yes |
Display |
LCD, 36,5 x 24mm |
Working temperature |
0 – 40 °С |
Storage temperature |
- 20 – -60°С |
Woring humidity |
<80 %,0 – 30 °С <75, 30 – 40 °С <45,40 – 50 °С |
Power source |
2xAAA 1.5V battery |
Size |
210 x 53x35mm |
Weight |
163,7g |